Skip to main content
    2026 Verified
    codes@speccodes.com
    Los Angeles County, California

    Santa Clarita ADA Signage Requirements

    2026 Title 24 & IBC Compliant Signs for Santa Clarita

    2026 Code Verified

    Last verified: Jan 30, 2026

    Quick Facts: Santa Clarita ADA Signage Requirements

    • Mounting Height: 48-60 inches AFF to centerline per CBC 11B-703.4.1
    • Geometric Symbols: Required per Title 24 11B-703.7.2.6 (12" triangle for men, 12" circle for women)
    • Photoluminescent Signs: Required by local amendment for commercial buildings
    • All-Gender Signage: Required for single-user restrooms per CA AB 1732
    • Code Edition: CBC 2025 Triennial with Santa Clarita Local Amendments

    Local Note: Santa Clarita Building & Safety requires photoluminescent exit signs in ALL commercial occupancies over 3,000 sq ft, per local amendment to CBC 2025.

    Verified by SpecCodes Compliance TeamLast updated: Jan 30, 2026

    Verification Status

    VERIFIED

    Last Verified

    Jan 30, 2026

    Code Edition

    CBC 2025 Triennial with Santa Clarita Local Amendments

    Next Review

    February 2026

    This information reflects our interpretation of the code. Your local Authority Having Jurisdiction (AHJ) has final authority on compliance matters.

    Santa Clarita ADA Sign Requirements 2026

    RequirementSpecificationCode Reference
    Mounting Height48-60 inches to centerlineCBC 11B-703.4.1
    Sign PlacementLatch side of doorCBC 11B-703.4.2
    Braille Spacing1/10" from tactile charactersCBC 11B-703.3.1
    Contrast Ratio70% minimumCBC 11B-703.5
    Geometric Symbols1/4" circle (women), 1/4" triangle (men)CBC 11B-703.7.2.6
    Photoluminescent SignsRequired (local amendment)Local
    Seismic BracingRequired for signs over 20 lbsCBC Chapter 17

    Santa Clarita Local Amendments

    These local code amendments are stricter than or in addition to state requirements.

    SCMC Local Amendment

    Photoluminescent Signage

    Required in ALL commercial occupancies over 3,000 sq ft (stricter than LA)

    Jan 1, 2025

    LA County Fire Code

    Exit Pathway Marking

    Photoluminescent pathway marking required in stairwells

    Jan 1, 2025

    Common Inspection Failures in Santa Clarita

    Based on inspection data, these are the most common signage-related failures:

    Sign Placement (latch side)25%
    Mounting Height18%
    Braille Spacing16%
    Missing Tactile Characters14%
    Contrast Ratio11%

    Santa Clarita Pre-Inspection Checklist

    • Verify photoluminescent signs if building over 3,000 sq ft
    • Check photoluminescent pathway marking in stairwells
    • Confirm mounting height is 48-60 inches to centerline
    • Verify seismic bracing for signs over 20 lbs
    • Check Braille spacing per Title 24
    • Confirm California geometric symbols on restroom signs

    Local Compliance Requirements

    Photoluminescent Signs Required
    Seismic Bracing Required

    Inspector's Note

    Santa Clarita Building & Safety requires photoluminescent exit signs in ALL commercial occupancies over 3,000 sq ft, per local amendment to CBC 2025.

    Santa Clarita, CA Code-Compliant Signage Authority

    Authority Having Jurisdiction (AHJ)

    • Local building department has final authority on code interpretation
    • Local amendments may apply beyond state and federal codes
    • Always verify requirements with AHJ before installation

    Common Local Variations

    Santa Clarita
    Photoluminescent signs required
    Santa Clarita
    Seismic bracing required (20+ lbs)
    2026 Code Verified
    ADA 2010 Compliant
    Title 24 11B
    IBC 2026

    Last verified: Jan 30, 2026CBC 2025 Triennial with Santa Clarita Local Amendments

    Santa Clarita Signage FAQ

    Need Help with Santa Clarita Compliance?

    Our code specialists can verify your specific requirements before ordering.